In the case below, 0.2 m³ of a grade rated at 145 kg/m³ for toluene holds 29 kg. Divided by the toluene load per hour from measured vent flow and concentration, this mass gives hours of service. Change-out comes earlier, when the outlet reaches its limit.
Working capacity comes from a data sheet or test that states concentration, humidity, temperature and the breakthrough criterion, checked for fit to the real stream. A D6646 result is accelerated and does not reproduce field conditions.
Moisture and heat both reduce physical adsorption. According to the EPA Air Pollution Control Cost Manual, water competes for adsorption sites above about 50% relative humidity, and typical operation lies between 77 and 104 °F. Reheating a humid stream lowers relative humidity and raises temperature at once, so the net effect is calculated. Grades impregnated for H₂S rely on a water film for the reaction, and the data sheet sets their humidity window.
The estimate is confirmed at the outlet with a method suited to the compound, such as an electrochemical sensor for H₂S. Detector limits and lead-lag operation are covered in the VOC article. Spent media is reactivated or disposed of after waste characterization.
Torch-Air selects activated carbon grades and chemical impregnation to match the customer's contaminants, operating conditions and required outlet concentration. For a quotation, send airflow, each compound with its minimum and maximum concentration, temperature, relative humidity, dust and aerosol load, and the operating schedule.