An industrial VOC air purifier treats exhaust from hoods, booths and process equipment before it reaches the stack. Its design starts with where the vapors are captured and how many pounds of solvent per hour the stream carries.

Local Exhaust and Process Vents

An industrial-strength air purifier for VOCs works on a ducted stream, so the first design decision is where vapors enter the duct. General dilution ventilation of a shop moves large air volumes at low concentration, and treating all of that air calls for an oversized unit. A hood, booth or enclosure draws vapors at the source: the treated flow is smaller, the concentration higher, and a compact unit can hold a defined outlet value. Capture efficiency of the hood sets how much of the emission reaches the treatment stage at all.

Process vents from dryers, reactors, coating lines or tank breathers carry a continuous or cyclic load and usually face a permit limit at the stack. Whatever the source, ask the equipment supplier for removal efficiency on named substances with the test concentration, flow, temperature, humidity and time to breakthrough. Gas-phase air-cleaning devices are tested under ASHRAE 145.2.
SIROCCO for breathing valve
SIROCCO for breathing valve

Industrial Air Purification Methods for VOCs

Adsorption suits aromatics, chlorinated solvents and other compounds with a higher molecular weight and boiling point. Small polar molecules such as methanol and formaldehyde are held weakly by carbon; for them, chemisorbents like potassium permanganate on alumina react with the gas and oxidize it. Where humidity cuts the capacity of carbon, hydrophobic high-silica zeolites are an option. Natural zeolites are hydrophilic and do not suit humid streams. Our SIROCCO adsorbers are rated at 6,000 cfm with about 200 Pa of pressure drop and take a prefilter, droplet separator and spare sorbent cartridges as options. An adsorber we designed for the vent of a toluene dissolver tank, filled and emptied every 3 hours, holds 0.2 m³ of special carbon rated at 145 g of toluene per dm³, about 29 kg per charge.
Schematic of a tank vent adsorber for VOC removal.
Schematic of a tank vent adsorber for VOC removal.
Absorption in a wet scrubber works for water-soluble compounds: methyl and ethyl alcohol, acetone, phenols, formaldehyde and other aldehydes. They pass into the liquid on random or structured packing. Our TORNADO RP wet scrubbers treat 600–30,000 cfm per module and are built of polypropylene, PVDF or steel. Saturation of the solution limits efficiency. In a semiconductor project with 100 scfm and 15 ppmv of IPA, removal reached about 99.9% with fresh water and dropped below 90% once the recirculated liquid held 5% alcohol. A labyrinth droplet eliminator comes standard on this model, and heavier carryover calls for a separate unit from our mist and droplet eliminators.

Oil mist, smoke and paint overspray coat sorbent granules and block the pores. In machining exhaust, oil mist collectors remove the aerosol ahead of the adsorber.

Biofiltration relies on microorganisms in a moist bed that oxidize biodegradable compounds at low concentrations. It fits steady, large flows and tolerates long shutdowns poorly. Torch-Air manufactures biofilters for such duties.

Thermal and catalytic oxidation suit high mass loads, where sorbent replacement costs more than burning the vapors.
TORNADO RP Vertical Wet Scrubber
Performance:
600 — 24 000 cfm
Sirocco Adsorber
Performance: 6000 cfm
Adsorber Sirocco Flow
Performance: 0 - 4000 cfm
Mist Modular Air Oil Mist Filter
Performance:
600 — 7000 cfm

Equipment Selection

Equipment for industrial air purification for VOCs is chosen from measured stream data. Flow is needed twice: in scfm for the mass load and in acfm at actual temperature and pressure for sizing. Add the concentration of each compound, relative humidity, aerosol and dust content, operating schedule and the required outlet value.
VOC Wet Scrubber An Effective Air Pollution Solution A Comprehensive Guide to Air Purification

Carbon Adsorber Sizing Example

The mass load is calculated from flow at stated standard conditions, while bed area and contact time use the actual flow through the vessel. Equilibrium capacity comes from an isotherm; the example uses the toluene isotherm in the EPA Air Pollution Control Cost Manual. Where no working-capacity data exist, the same manual allows a preliminary estimate of 50% of equilibrium capacity. Superficial velocity comes from the media supplier; vendor values cited there run from 60 to 85 ft/min.
The run time is a mass-balance estimate. Hours until the outlet reaches 5 ppmv depend on the mass-transfer zone and are read from the supplier's breakthrough curve at actual humidity and temperature. Above 50% RH water competes for adsorption sites, most noticeably at low concentrations, and capacity falls. At roughly 170 lb of media per shift, a regenerable system deserves a cost comparison.
Overview | Adsorber filters adsorb carbon dioxide gas from the air

Operation and Media Change-Out

The change-out point equals the outlet limit. In a lead-lag arrangement, gas is sampled between the two vessels; when the lead bed reaches the limit, it receives fresh media and moves to the lag position.

The analyzer must detect the target compounds. A photoionization detector responds only to substances whose ionization energy is below the lamp energy, so a 10.6 eV lamp misses formaldehyde (10.88 eV) and methanol (10.84 eV). Formaldehyde requires a dedicated method.

Ketones, aldehydes, organic acids and peroxides can react exothermically on carbon and form hot spots. Keeping the stream below 25% of the LEL does not rule out this thermal risk. Heating is limited by diluting the inlet air or spreading a high inlet load over time, and the vapors should be tested on the chosen carbon before start-up. Bed temperature and CO are monitored in service. Shutdown follows the unit design and an approved procedure, because air drawn over hot carbon can supply oxygen for a fire.

Spent media is characterized as waste before it leaves the site. Depending on what it holds, it may fall under RCRA hazardous waste rules or return for reactivation. On scrubbers, operators track the L/G ratio, pH or ORP, blowdown rate and pressure drop across the droplet eliminator.
Join the Conversation!
Share your thoughts on this article, rate it, or spread the word by sharing it with others.
Your feedback is appreciated!
quotation mark
We always perform precise calculations and offer expert assistance in selecting the optimal dust collection or gas cleaning systems, typically completing this process within 1 to 2 days
Head of Engineering,
Vladimir Nikulin
CALCULATION AND SELECTION
After filling out this form, you will obtain the cost of the equipment and time frame over which it will be delivered
quotation mark
phone
message
email
By filling out this form, you agree to our personal data processing policy
DELIVERY AND INSTALLATION ALL OVER USA, CANADA, MEXICO
FULL ADHERENCE TO QUALITY STANDARDS
WE CUSTOMIZE INSTALLATIONS TO SUIT YOUR COMPANY
FAVORABLE PRICES FROM A US MANUFACTURER
Map
Operating in USA, Canada, and Mexico
Black torch