Alarm | Possible Cause |
High differential pressure | Clogged sleeves, failed cleaning system |
Low differential pressure | Bag rupture, bypass valve open |
High gas temperature | Exceeds allowable limit for filter material |
Low air pressure (cleaning) | Compressor fault, leakage in air line |
High dust emission | Filter damage, leaks in housing or sealing issues |
Frequency | Action |
Daily | Check ΔP, gas temperature, and pulse cleaning performance |
Weekly | Inspect hopper and dust discharge system |
Monthly | Inspect bag condition, check valve operation |
Quarterly | Test cleaning and alarm systems |
Annually | Perform full equipment audit, replace worn bags |
Sector | Standard | Emission Limit |
Cement Plants | 40 CFR Part 60 Subpart F | <30 mg/dscm |
Coal-fired Power | 40 CFR Part 63 Subpart UUUUU | <0.03 lb/MMBtu (PM) |
Metal Processing | 40 CFR Part 63 Subpart XXXXXX | Limits on PM and specific metals |
Wood Products | 40 CFR Part 63 Subpart DDDD | Requires baghouse & leak detection |